DNA Heating & Air conditioning Inc

DNA Heating & Air conditioning Inc A mechanical-based company committed to providing the highest-quality services in heating, air conditioning, and refrigeration.

We offered services across various sectors, including residential, commercial, industrial, and non-profit organizations.

*****Jay Swaminarayan*****Happy Diwali 2025! Let’s light up the skies with joy, gratitude, and celebration. May this daz...
10/20/2025

*****Jay Swaminarayan*****
Happy Diwali 2025! Let’s light up the skies with joy, gratitude, and celebration. May this dazzling festival of lights fill your life with peace, happiness, and the courage to conquer any darkness. Wishing you and your family an absolutely fantastic and joyful Diwali!
ASHISH PAREKH

DNA Heating and Air conditioning Inc.

08/14/2025
**Chilled Water Coil System Diagnosis**@ In a multi-coil chilled water air handling unit, diagnosing a unit that has bee...
07/24/2025

**Chilled Water Coil System Diagnosis**

@ In a multi-coil chilled water air handling unit, diagnosing a unit that has been leaking or causing condensate water to exit the drain line can be challenging. I would like to present two methods for diagnosing this issue.

During the summer months, the cooling system works very hard, making it difficult to determine whether the chilled water is leaking. My preferred method for diagnosis involves isolating the chilled water and the condensate water.

To begin, I would close the supply water valve to all the coils in the large air handling unit and monitor the temperature difference between the mixed air temperature and the supply air temperature over a certain period. As the system operates, the supply air temperature will rise to match the mixed air temperature and may even increase slightly above that point. This rise indicates that the mechanical energy is contributing to the supply temperature, while the coil is receiving the same air temperature as the chilled water inside.

During this monitoring period, if we observe that the drain line gradually slows down and the water temperature decreases almost like a heartbeat, this suggests that the coil has no leaks. This method allows us to check multiple coils simultaneously. By stopping the circulation, no additional condensation is created from the water unit, making it easier to identify any leaks or condensation issues.

In this method, we have shut down only one side of the circulation service valve. The water trap inside is not receiving frequent temperature changes, resulting in no circulation, no thermal changes, and no condensed water. The system already maintains pressure within the chilled water loop. If there are any leaks, we would expect to see more water exiting instead of just a slow drop like a heartbeat.

The inside condition of the horizontal pipe is showing signs of rusting.
05/02/2025

The inside condition of the horizontal pipe is showing signs of rusting.

Enjoying Beauty of the nature @ New property start up 
05/01/2025

Enjoying Beauty of the nature @ New property start up 

10/23/2024
10/20/2024
10/20/2024

0 Followers, 0 Following, 4 Posts - See Instagram photos and videos from DNA-Heating &Air Conditioning ()