Touch Safe

Touch Safe Electrical Safety for Portable Appliances. PAT Testing software that makes managing your items simp

New outdoor socket for a home in Cheddar
19/03/2025

New outdoor socket for a home in Cheddar

Outdoor heaters installed for this garden gazebo. 👌
11/07/2021

Outdoor heaters installed for this garden gazebo. 👌

 outdoor socket doing the job
09/07/2021

outdoor socket doing the job

Before and after. boards upgrade.
16/03/2021

Before and after.
boards upgrade.

04/03/2021

Flexi conduit wins every time... Distribution circuit and small outbuilding consumer unit installation.

Nest Hello Doorbell installation with plugin transformer and socket outlet.
24/02/2021

Nest Hello Doorbell installation with plugin transformer and socket outlet.

This is another reason why EICRs are so important.An elderly gentleman called us saying his fuseboard was hot and could ...
18/02/2021

This is another reason why EICRs are so important.
An elderly gentleman called us saying his fuseboard was hot and could smell burning. I guess few more minutes and it would have ignited the whole board and house with it!

You can just see in this photo that just 2 of the conductors of this multi stranded 6mm cooker cable have been connected, leaving the rest hanging behind. Result was reduced currently carrying capacity, overheating and then combustion....

Not surprisingly every termination in the board was also loose!

Very close call.....

An example of why it's important to remove and inspect faceplates during EICRs. Here the insulation has been pinched, ma...
08/12/2020

An example of why it's important to remove and inspect faceplates during EICRs. Here the insulation has been pinched, making a poor connection and high fire risk.

Another happy customer with a Nest Thermostat installed. This great gadget saves you money on your heating bills and giv...
03/11/2020

Another happy customer with a Nest Thermostat installed. This great gadget saves you money on your heating bills and gives you ease of use and stylistic design.

A busbar showing signs of arcing. Symptoms: crackling sounds coming from the circuit breaker.Cause: loose connection bet...
16/10/2020

A busbar showing signs of arcing.
Symptoms: crackling sounds coming from the circuit breaker.
Cause: loose connection between circuit breaker base and busbar.

Keep your home safe
08/10/2020

Keep your home safe

06/10/2020

A working smoke alarm gives you valuable time to escape if a fire breaks out in your home.