Quoted repair at a post-acute care facility in Woodbury, NJ β€” followed up on a grounded condenser fan motor flagged duri...
08/12/2026

Quoted repair at a post-acute care facility in Woodbury, NJ β€” followed up on a grounded condenser fan motor flagged during our service call.

πŸ”§ Installed a new condenser fan motor and contactor
πŸ”§ Cleaned the condensers
βœ… All three compressors running β€” chiller back up and operating

In a healthcare setting, reliable cooling isn't optional.

πŸ“© Reach out β€” we'll figure it out.

08/08/2026

Quoted repair at a used car dealership in New Castle, DE β€” two condensate pumps flagged during a recent PM visit.πŸ”§ Repla...
08/06/2026

Quoted repair at a used car dealership in New Castle, DE β€” two condensate pumps flagged during a recent PM visit.

πŸ”§ Replaced both defective condensate pumps
πŸ”§ Leveled and secured both units
βœ… Pumps running and draining as they should

Quoted repair at a laser hair removal clinic in Springfield, PA β€” refrigerant leak on one of the rooftop units.πŸ”§ Repaire...
08/04/2026

Quoted repair at a laser hair removal clinic in Springfield, PA β€” refrigerant leak on one of the rooftop units.

πŸ”§ Repaired the leak on the coil
πŸ”§ Installed a new filter drier
πŸ”§ Recharged the system with R-410A
βœ… Unit running and cooling properly

A leaking coil doesn't announce itself β€” it just quietly reduces performance until the system can't keep up anymore. Caught, repaired, recharged.

πŸ“© Have an HVAC issue? Reach out and we'll take a look.

Service call at a retail jewelry store in Langhorne, PA β€” staff reported the thermostat wasn't working properly.Found a ...
07/30/2026

Service call at a retail jewelry store in Langhorne, PA β€” staff reported the thermostat wasn't working properly.

Found a pneumatic thermostat controlling a chilled water valve β€” a system type common in older mall locations where cooling is supplied centrally rather than by a rooftop unit.

Tested the operation end to end. Turned the thermostat up β€” valve closed, supply air measured 74.5Β°F. Turned it back down β€” valve opened, supply air dropped to 67Β°F. Chilled water from the mall coming in at 64Β°F.

System responding exactly as it should.

No repairs needed. Sometimes the right call is confirming everything is working correctly.

πŸ“© Contact us to get it looked at.

Service call at an optical retail store in Easton, PA β€” hot air in the break room and back offices while the front of th...
07/28/2026

Service call at an optical retail store in Easton, PA β€” hot air in the break room and back offices while the front of the store was perfectly comfortable.

Both units were running. No mechanical issues.

πŸ” The unit serving the back of the store had only a 2Β°F differential between heating and cooling setpoints β€” narrow enough to cause the unit to bounce back and forth between the two modes constantly.

Adjusted the differential to 4Β°F and synced both units to the same schedule and setpoints.

βœ… No parts. No repairs. Units running correctly.

Quoted repair at a retail jewelry store in Pottstown, PA β€” followed up on a unit that had been struggling through the he...
07/24/2026

Quoted repair at a retail jewelry store in Pottstown, PA β€” followed up on a unit that had been struggling through the heat.

πŸ”§ Installed new condenser fan motor, blade and capacitor
πŸ”§ Replaced the compressor contactor
πŸ”§ Chemically cleaned the condenser coil
πŸ”§ Replaced blower belt and air filters
βœ… Checked pressures and took temp readings β€” unit running and cooling properly

The store that couldn't get below 80Β°F on a hot day is back to holding setpoint.

πŸ“© DM us to schedule the service.

Service call at a retail jewelry store in Pottstown, PA β€” AC couldn't keep up on the hottest days of the year. Store was...
07/23/2026

Service call at a retail jewelry store in Pottstown, PA β€” AC couldn't keep up on the hottest days of the year. Store was hitting 80Β°F with the thermostat set to 64Β°F.

Found the unit struggling on multiple fronts.

πŸ” Plugged air filters blocking return airflow. Blower belt loose and falling apart. Condenser coils dirty. Compressor contactor pitted. Condenser fan bearings grinding.

When several things go wrong at once, the system doesn't fail dramatically β€” it just slowly stops keeping up. Until a 100Β° day exposes everything at once.

Replaced the belt with a spare on-site, pulled the plugged filters, and sprayed the evaporator coil with self-rinsing cleaner to get the unit running better immediately. Quote submitted for the full repair.

πŸ“© DM us when something doesn't seem right.

July PM at a retail jewelry store in Langhorne, PA.Changed filters, cleaned condensate traps, inspected electrical conne...
07/21/2026

July PM at a retail jewelry store in Langhorne, PA.

Changed filters, cleaned condensate traps, inspected electrical connections and blower assemblies, took temp readings.

Found one of the rooftop unit doors laying on the roof β€” reinstalled and secured it properly with new screw holes.

Everything else checked out. System running well heading into the hottest stretch of summer.

πŸ“© DM us when something doesn't seem right.

Service call at a laser hair removal clinic in Blue Bell, PA β€” manager reported wet floors, hot air coming from the retu...
07/17/2026

Service call at a laser hair removal clinic in Blue Bell, PA β€” manager reported wet floors, hot air coming from the return grille, and an unusual odor inside the space.
Went up on the roof and found the filter access door had come loose β€” the screws had pulled out of the mounting strip, and the door had slid down onto the economizer hood. Wide open.
After a rainy weekend, the unit had been pulling in outdoor air, humidity, and everything that comes with it β€” including odors from the neighboring restaurant. All of it going straight into the space below.
πŸ”§ Reinstalled the filter door and secured it properly β€” new screws going directly into the unit instead of the strip, so it won't happen again.
βœ… Took temp readings and verified operation. Unit running and cooling properly. No more odors, no more wet floors.
Two calls in a row where the unit itself was fine β€” just something on the outside that shouldn't have been open, was.
πŸ“© DM us when something doesn't seem right.

Address

201 E Pennsylvania Boulevard
Philadelphia, PA
19053

Opening Hours

Monday 7am - 7pm
Tuesday 7am - 7pm
Wednesday 7am - 7pm
Thursday 7am - 7pm
Friday 7am - 7pm
Saturday 10am - 7pm

Telephone

+12156077728

Alerts

Be the first to know and let us send you an email when Summit HVAC posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Summit HVAC:

Shortcuts

Featured

Share