One room, moving in three different directions at once. Here's why.
The rear rumpus room in this home wasn't just subsiding, it was subsiding unevenly, with different sections of the same room moving in different directions and at different rates. Floor level readings told the story clearly, with movement ranging across the room rather than settling as one unit.
The cause was a combination working against the structure at once. Both the sewer and stormwater services had been leaking over time, and that constant moisture was soaking into highly reactive clay beneath the room, gradually breaking down the ground's surface integrity.
To correct it, we carried out multiple injections across approximately 15 lineal metres, targeting the full length of the affected area rather than isolated points.
The result: complete footprint re-engagement of the drop edge beam and raft slab, with levels returned to within 3mm of level, restoring even, reliable support across the entire room.