Ultrasonic Pulse Velocity - UPV

Ultrasonic Pulse Velocity - UPV EN12504-4, ASTM C597-02, BS1881, ISO1920-7, CECS21
Ultrasonic Pulse Velocity (UPV) Punditlab+ Perth Construction Testing Services (PCTS) www.pcts.com.au

Ultrasonic Pulse Velocity (UPV) of steel reinforced concrete structures. This test operates on the principle that stress wave propagation velocity is affected by quality of concrete. Pulse waves are induced into the test object and the time of arrival is measured at the receiving surface. Electromagnetic timing circuits enable the transit time (T) of the pulse to be measured. Longitudinal pulse ve

locity (in km/s or m/s) is given by:
V = L / T
Where V = Pulse Velocity, L = Path Length and T = time taken by the pulse to traverse that length.