12/06/2023
New Baxi 830 Combi 2 installation.
• System conversion - removed system boiler, cylinder, tanks and cleared loft space.
• Upgraded gas supply pipe to the boiler to achieve correct gas inlet pressure & gas drop from meter.
• New vertical flue system & lead flashing.
• Upgraded system controls to achieve better efficiency, installed weather compensation and load compensation thermostat.
• Flushed and cleaned system with Sentinel X400 and on final fill added X100 inhibitor.
•Installed all appropriate system components to comply with the 10 year warranty.
• Installed three zones - heating system, towel rail, UFH manifold. Each zone with separate channels for best control of each zone and independent timing. This was done as the customer wanted the boiler to heat the towel rail throughout summer without heating the whole system.