Pro-Lec Scotland Limited

Pro-Lec Scotland Limited We’re NICEIC approved electricians, carrying out domestic and commercial work in Edinburgh and the Lothians


All work undertaken. All work undertaken.

Pro-Lec is an Edinburgh based company offering a wide variety electrical services with years of professional experience.

Not what you expect to find when you attend a suspected storage heater not working. Cause by what was most likely a slac...
14/05/2026

Not what you expect to find when you attend a suspected storage heater not working.

Cause by what was most likely a slack connection in the “screwfix special” board. Installed by a known cowboy electrician based in Edinburgh - who isn’t with a register body. Circuits not identified. No certification. No proof of testing.

The same electrician installed the meter tails around arse for elbow on the main consumer unit too 🤠

When testing our new board we discovered that the cpc wasn’t connected to the immersion and that the off-peak immersion was tripped. The customer had been using the boost every morning. So we’ve fixed that too for a cup of tea. Oh, and issued a certificate for the work with our NICEIC registration.

The joys

04/05/2026

Never liked pigeons. 🐦🤬

“Are you off for the bank holiday weekend?”Yeah off to work. Saturday morning consumer unit install at our rewire. Type ...
02/05/2026

“Are you off for the bank holiday weekend?”

Yeah off to work.

Saturday morning consumer unit install at our rewire.

Type A RCD protection ✅
Surge protection ✅
Unpaid overtime ✅

Apprentice in the making ⚡️
10/04/2026

Apprentice in the making ⚡️

Recently completed job ⚡️Consumer unit upgraded and converting single sockets into doubles + installing additional socke...
04/02/2026

Recently completed job ⚡️

Consumer unit upgraded and converting single sockets into doubles + installing additional sockets on brick walls with little to no damage.

Bob the (previous next door neighbour) builder, Can he fix it? Bob the (previous next door neighbour) builder, Can he F*...
31/01/2026

Bob the (previous next door neighbour) builder,
Can he fix it?

Bob the (previous next door neighbour) builder,
Can he F*ck.

Another valid example of “just use an electrician”

A cold running shower within its warranty period so Mira was called out to repair but refused. The first time I’ve seen Mira condem a shower. (They also charge a call-out fee)

I was then contacted to do repair properly. All It needed was the 3” of brick raggled out to allow some more length on the cable to connect it straight in without the “extension”.
How this didn’t arc/burnt-out is beyond me.

P.s if you have a faulty out of warranty electric shower, we repair them too. 🚿

07:25 - Potty training toddler soils himself at breakfast 07:40 - I need to head back home because I left my phone 07:50...
30/01/2026

07:25 - Potty training toddler soils himself at breakfast

07:40 - I need to head back home because I left my phone

07:50 - Van tyre pops

Is it the weekend yet?

Another EICR find. 🔍Stranded Steel wiring was typically installed in the 1960/70’s before we switched to copper wiring. ...
27/01/2026

Another EICR find. 🔍

Stranded Steel wiring was typically installed in the 1960/70’s before we switched to copper wiring. The insulation is falling off the steel cores it’s so worn. Unfortunately the masking tape repair doesn’t offer the same level of protection as insulation. I saw the chance to throw in a pun then but passed on the opportunity.

Rewire to the circuit required.

Curious to know who changed the consumer unit last year and deemed the circuit safe for continued use.

The next time DIY Dave offers to connect up your oven just tell him to f*ck off 🤠 Today’s EICR find we have 🔍An exposed ...
22/01/2026

The next time DIY Dave offers to connect up your oven just tell him to f*ck off 🤠

Today’s EICR find we have 🔍

An exposed joint for the oven. No joint box used, exposed live parts, the incorrect size crimps used and the cores cut down to accommodate.

Then had they tested the cable was safe for use, they’d have discovered that the live and neutral were reversed polarity and that the earth wasn’t connected.

So had that exposed cable touched the oven housing, the housing would become live.

This is why we do EICR’s and why you should use and electrician

I need a coffee.

Half the day spent in Harry Potter’s bedroom upgrading this monstrosity. Surge Protection ✅Type A RCD protection ✅
14/01/2026

Half the day spent in Harry Potter’s bedroom upgrading this monstrosity.

Surge Protection ✅
Type A RCD protection ✅

14/01/2026

Apology to whoever needs it.

After experiencing a “chirping” smoke alarm in the middle of the night and unfortunately finding something harder to try sleep through than Emma’s snoring after a night out. We’ve now made it our promise to drop whatever we’re doing and attend any beeping smoke alarm immediately, because that was bloody annoying.

I’d also like to apologise to anyone who caught me in my boxers, after peeling myself out my bed and getting 9v battery out the back of the van late last night.