CD Electrical

CD Electrical With over 35 years in the electrical industry, get in touch for any electrical enquiries. Over 30 years experience in the Electrical Industry.
(1)

Couple of board upgrades on Hayling Island, a lot of energy suppliers are now stopping the economy 7 (off peak) tariff &...
30/09/2024

Couple of board upgrades on Hayling Island, a lot of energy suppliers are now stopping the economy 7 (off peak) tariff & Storage heaters are ineffective & costly to use, so a lot of our customers are switching to Ronite or similar electric heaters, for these to work during the day (when you actually want heat) you have to remove the economy 7 board & the best way to do this is to fit a larger board to replace both old boards, we usually fit Contactum Ltd main switch boards with Surge Protection & individual RCBO, these offer excellent protection & are very well made boards. Get in contact if you want to upgrade your old fuseboard. We use BEW Electrical Distributors Ltd for all of our electrical supplies.

Call yesterday for a shower not working, I think that’s the worst burnt out switch I’ve ever seen, lucky there was enoug...
12/06/2024

Call yesterday for a shower not working, I think that’s the worst burnt out switch I’ve ever seen, lucky there was enough cable to cut back, re terminate & fit a new switch.

This 4 x 25mm SWAcable was hit by a JCB while digging, it wasn't run in properly, so it's going to be dig in to the corr...
12/06/2024

This 4 x 25mm SWA
cable was hit by a JCB while digging, it wasn't run in properly, so it's going to be dig in to the correct depth & electrical warning tap over the top so hopefully this won't happen again. Repaired with this torpedo joint.

Installed some lovely dining room lights today at a property in Sheer for one of our oldest customers, they looked absol...
08/12/2023

Installed some lovely dining room lights today at a property in Sheer for one of our oldest customers, they looked absolutely stunning.

3 phase board & generator change over panel removed & a single phase distribution board fitted with individual RCBOs & S...
16/11/2023

3 phase board & generator change over panel removed & a single phase
distribution board fitted with individual RCBOs & SPD, get in contact for any electrical needs.

Strip out this 3 phase board & standby generator control panel & battery charger in a farm in Emsworth, ready for a new ...
19/10/2023

Strip out this 3 phase board & standby generator control panel & battery charger in a farm in Emsworth, ready for a new single phase board, once in the current single phase boards will be removed & the circuits moved over.

High level lighting going up today at this motor company in Leatherhead, using Ansell Lighting fittings. Get in touch if...
27/09/2023

High level lighting going up today at this motor company in Leatherhead, using Ansell Lighting fittings. Get in touch if you need an workshop/garage fit outs.

25/09/2023
Another garden lighting project we completed in Albury using  spike lights  boxes & Gel &  cable connectors, all materia...
07/04/2023

Another garden lighting project we completed in Albury using spike lights boxes & Gel & cable connectors, all materials supplied by the customer was incredibly happy with the lighting. Get in contact if you require any electrical work.