DWSPARKSELECTRICALSERVICESLtd

DWSPARKSELECTRICALSERVICESLtd Contact information, map and directions, contact form, opening hours, services, ratings, photos, videos and announcements from DWSPARKSELECTRICALSERVICESLtd, Electrician, Islington, London.

D.W Sparks Electrical Services provides trusted domestic and commercial electrical work across Islington, King’s Cross and North London, including EICRs, consumer unit upgrades, rewires, fault finding, lighting installations and emergency call-outs.

Upgraded today from an older style fuse board to a modern RCBO consumer unit 🔧The previous board was from an earlier edi...
31/03/2026

Upgraded today from an older style fuse board to a modern RCBO consumer unit 🔧

The previous board was from an earlier edition and didn’t provide the level of protection expected by current standards. It’s now been replaced with a fully compliant RCBO board, giving individual circuit protection, improved fault detection, and much better safety overall.

All circuits tested, certified, and brought up to current regulations. Another property made safer and future-ready ⚡

If your fuse board is outdated, it might be time to consider an upgrade.

EICR Observation – No Zs on DownlightsNo Zs readings were obtained on metal can downlights when tested with a GU10 plug-...
30/03/2026

EICR Observation – No Zs on Downlights

No Zs readings were obtained on metal can downlights when tested with a GU10 plug-in tester.

Fittings were removed and found to have basic insulation throughout, with CPCs cut out to the cans leaving them unearthed. Accessible connections were rectified.

Further investigation required cutting into the ceiling, where a taped joint with no earth present was found. Connection has now been remade correctly with earth continuity restored.

Installation previously left in a potentially dangerous condition.

Got called out to fit a dishwasher today, but as always decided to test everything beforehand — glad I did.Turns out the...
25/03/2026

Got called out to fit a dishwasher today, but as always decided to test everything beforehand — glad I did.

Turns out the flat had a high Ze reading and no RCD protection on the fuse board. Measured Ze at 58.4Ω on what should be a TN-S system 🚩 Definitely not right.

Had to stop the job and get the DNO involved to investigate the earthing. Just goes to show why testing first is so important — could’ve been a serious safety issue if it was just installed and left.

Stay safe and always check before you connect ⚡

A beautiful upgrade using the customer’s own antique lights ✨We recently carried out a dining room and hallway lighting ...
19/03/2026

A beautiful upgrade using the customer’s own antique lights ✨

We recently carried out a dining room and hallway lighting change, carefully installing the customer’s antique fittings to bring character and charm back into the space. These pieces really make a statement and add a unique, timeless feel you just can’t replicate with modern fixtures.

Now the home feels warmer, more elegant, and full of personality 💡

Always a pleasure working with such special pieces — what a transformation!

⚠️ Kitchen looks great… but what about the electrics behind it? ⚠️We’ve recently come across installations carried out b...
18/03/2026

⚠️ Kitchen looks great… but what about the electrics behind it? ⚠️

We’ve recently come across installations carried out by kitchen fitters where:
❌ Sockets are poorly terminated
❌ CPCs (earths) incorrectly sleeved in blue or brown
❌ Fused spur supplies and loads completely mixed up

This isn’t just untidy work — it’s unsafe.

Your home’s electrical system isn’t something to cut corners on. Incorrect wiring can lead to faults, electric shock risks, or even fire hazards 🔥

💡 Ask yourself:
👉 Do you know who is installing your electrics?
👉 Are they properly qualified and certified?
👉 Will they test and sign off the work correctly?

Just because someone can fit a kitchen doesn’t mean they’re trained to carry out electrical work safely.

✅ Always use a qualified electrician
✅ Always request certification
✅ Always make safety your priority

If you’re unsure about recent work or want peace of mind, get it checked.

📩 Message us today for an inspection or advice — because safe electrics aren’t optional, they’re essential

🔧 Height? No problem! 🪜Today’s job: safely disconnecting an old, unused security alarm system and removing the external ...
11/03/2026

🔧 Height? No problem! 🪜

Today’s job: safely disconnecting an old, unused security alarm system and removing the external equipment, making everything ready for a brand new system to be installed.

✔ Old control panel and wiring removed
✔ External alarm box taken down
✔ Power safely isolated
✔ Property left ready for the new installation

Whether the job is high up, awkward to reach, or in tight spaces, the right equipment and experience makes it straightforward.

If you’ve got an old alarm system that needs removing, upgrading, or replacing, feel free to get in touch. Happy to help get everything ready for a modern setup.

🪜 Height work? Not a problem.
🔌 Safe electrical disconnection
🏠 Domestic properties welcome

Message me for a quote or advice.

Another interesting EICR find today 👀Attended a property today to carry out an Electrical Installation Condition Report ...
10/03/2026

Another interesting EICR find today 👀

Attended a property today to carry out an Electrical Installation Condition Report and found a few classics:

• Old rewireable fuse board still in service
• A radial socket circuit wired directly into an asbestos 45A rewireable fuse
• No RCD protection anywhere on the installation
• Metal pipework not bonded

This kind of setup was common years ago but highlights why periodic inspections are so important. Lack of RCD protection and missing bonding significantly reduces the safety of the installation.

Recommendations issued for consumer unit upgrade, RCD protection, and main bonding installation to bring the system up to a safer standard.

Always worth getting your installation checked if it hasn’t been inspected in years. ⚡

⚡ EICR Find of the Day – Loose MCB Connection ⚡During a recent EICR (Electrical Installation Condition Report) I discove...
10/03/2026

⚡ EICR Find of the Day – Loose MCB Connection ⚡

During a recent EICR (Electrical Installation Condition Report) I discovered an MCB that was not properly connected to the busbar inside the consumer unit.

At first glance everything looked normal, but on closer inspection the breaker was not fully seated and secured onto the busbar, which could lead to:❗ Overheating❗ Arcing❗ Intermittent power loss❗ Potential fire risk

This is why a thorough inspection matters. It's not just about ticking boxes – every breaker must be properly seated, tightened, and securely connected.

🔍 When was the last time your consumer unit was checked?Are your MCBs secure and properly connected to the busbar?

If you're a landlord, homeowner, or business owner, regular inspections help keep your property safe and compliant.

📩 Get in touch today to book your EICR inspection.

✨ New Lighting Installation Complete ✨Another clean transformation finished ✔️Installed these sleek modern wall lights t...
09/03/2026

✨ New Lighting Installation Complete ✨

Another clean transformation finished ✔️

Installed these sleek modern wall lights to completely upgrade the space — warm, stylish, and practical. The right lighting doesn’t just brighten a room… it changes the whole feel of it.

From subtle ambience to sharp feature lighting, we make sure every install is neat, safe, and built to last.

If you’re looking to upgrade your home, studio, office, or commercial space — now’s the time 💡

Still relying on an old fuse board with a single RCD — or worse, no RCD protection at all?If one appliance develops a fa...
08/03/2026

Still relying on an old fuse board with a single RCD — or worse, no RCD protection at all?

If one appliance develops a fault, does it cut power to your whole home? Constant nuisance tripping can be frustrating, and older boards without proper RCD protection may not provide the level of safety your property needs.

Now is the perfect time to upgrade to a new RCBO consumer unit with built-in Surge Protection Device (SPD)

Address

Islington
London
WC1X9HG

Alerts

Be the first to know and let us send you an email when DWSPARKSELECTRICALSERVICESLtd posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Shortcuts

Featured

Share

Category