RCD Tripping – when the real problem is hidden in the wiringA recent fault-finding visit was a good example of why repea...
15/08/2026

RCD Tripping – when the real problem is hidden in the wiring

A recent fault-finding visit was a good example of why repeated RCD tripping should never be treated as simply an “RCD problem”.

The customer reported that the RCD was repeatedly tripping, with the cooker circuit initially suspected as the likely cause.

After carrying out a full investigation, several separate electrical issues were identified.

🔎 What we found:

• The cooker circuit neutral was incorrectly connected to the neutral associated with a different circuit protected by a separate RCD. This created an unwanted neutral connection between circuits and was contributing to the RCD tripping.

• The CPC (Circuit Protective Conductor) to one circuit had been extended using a very poor DIY-style connection. The conductor was also coming into contact with the neutral bar, creating another potential fault condition.

• A kitchen light fitting showed low insulation resistance between neutral and CPC. The fitting was therefore replaced.

• The consumer unit itself had also been installed with far more capacity than was actually required for the installation, with a 15-way board being used for only five circuits. While spare capacity is not inherently a problem, the installation should always be designed appropriately for the actual requirements.

✅ All identified faults were rectified.

The defective light fitting was replaced, the incorrect neutral connection was corrected, the CPC issue was rectified and the installation was fully tested again.

The electrical installation is now operating correctly without the reported RCD tripping.

This is a good reminder that RCD tripping is a symptom, not necessarily the fault itself.

Correct diagnosis requires proper inspection, testing and fault-finding rather than simply replacing the RCD and hoping for the best.

At PowerOn Engineering, we investigate electrical faults systematically to identify the underlying cause and make the installation safe and reliable.

📍 Serving London & Kent
⚡ Fault Finding | Electrical Testing | Repairs | EICR | Consumer Units | Emergency Electrical Work

⚡ Need an Electrician?Fast. Reliable. Professional.✔ 24/7 Emergency Call-Out✔ Domestic & Commercial✔ Free Quotations📞 Ca...
10/08/2026

⚡ Need an Electrician?

Fast. Reliable. Professional.

✔ 24/7 Emergency Call-Out
✔ Domestic & Commercial
✔ Free Quotations

📞 Call or WhatsApp: 07511 635009

PowerOn Engineering Ltd – Electrical Solutions You Can Depend On.

⚠️ Looks can be deceiving. This inspection uncovered a serious safety issue.This property had a recent Electrical Instal...
03/07/2026

⚠️ Looks can be deceiving. This inspection uncovered a serious safety issue.

This property had a recent Electrical Installation Condition Report (EICR) carried out by an Approved Contractor.

However, during my investigation I discovered something far more concerning than untidy wiring…

❌ There was NO effective connection to earth from the supply.

This meant I was unable to obtain a valid Ze reading because the installation had no earth provided by the network.

A missing or ineffective earth connection is one of the most serious faults that can exist in an electrical installation. Without a reliable earth path, protective devices may not operate correctly during a fault, significantly increasing the risk of electric shock.

What makes this even more concerning is that the previous report recorded:
✔️ Ze = 0.14 Ω
✔️ 100A supply

…while the actual installation has a 60A service fuse, and the recorded Ze value simply could not be verified because there was no earth present.

This highlights an important point:

👉 An EICR is not about finding easy observations or making a consumer unit look tidy.

It’s about verifying that the installation is safe.

Unfortunately, I often see reports focusing on cosmetic issues while fundamental safety checks are either missed or not properly verified.

As electricians, our responsibility is to protect people — not just complete paperwork.

If you’re buying a property or have concerns about the quality of an electrical inspection, don’t assume that a recent EICR guarantees the installation has been properly tested.

PowerOn Engineering Ltd
⚡ Professional Fault Finding
⚡ EICR & Electrical Testing
⚡ Domestic & Commercial
⚡ Kent • South East London

🔧 Today’s job completed!A customer wanted improved fire protection and a few electrical upgrades, so today’s work includ...
23/06/2026

🔧 Today’s job completed!

A customer wanted improved fire protection and a few electrical upgrades, so today’s work included:

✔ Ring circuit extension with a new double socket
✔ Installation of 2 interlinked smoke alarms and 1 heat detector
✔ Testing and certification of the new installation
✔ Removal and decommissioning of an old fire alarm system

The old fire alarm equipment and associated wiring were removed, and the property now benefits from a modern interlinked detection system that provides much better coverage and reliability.

As always, all work was fully tested before completion and the property was left clean and safe.

Need additional sockets, smoke alarms, fault finding or any other electrical work?

📞 Contact PowerOn Engineering Ltd for a free quotation.

⚡ Domestic & Commercial Electrical Services
⚡ Kent & South East London
⚡ Fully Insured

🚨 Sunday call-out ! Circuit Breaker Keeps Tripping? We Found the Problem! 🚨Today’s job involved a ring circuit that kept...
07/06/2026

🚨 Sunday call-out ! Circuit Breaker Keeps Tripping? We Found the Problem! 🚨

Today’s job involved a ring circuit that kept tripping the breaker every time power was restored.

After carrying out fault finding, several hidden connection boxes were discovered. Unfortunately, the previous workmanship was poor, with connections incorrectly terminated and junction boxes installed on top of each other. To make matters worse, a recent bathroom leak had allowed water to enter some of the connections, causing further issues.

⚡ What we did:
✅ Located the source of the fault
✅ Opened and inspected all affected connections
✅ Correctly reconnected and secured conductors
✅ Installed suitable maintenance-free / water-resistant connection enclosures
✅ Replaced a faulty socket outlet
✅ Corrected an incorrectly connected outlet
✅ Fully tested the circuit
✅ Restored power and confirmed safe operation

The customer now has a fully functioning ring circuit with no tripping and peace of mind that the installation is safe.

If you’re experiencing tripping breakers, faulty sockets, damaged wiring or mysterious electrical faults, get in touch.

📞 07511 635009
📧 [email protected]

PowerOn Engineering Ltd
Electrical Solutions ⚡🔌

🚗⚡ Another EV Charging Point Successfully Installed! ⚡🚗Today we completed the installation and commissioning of a commer...
03/06/2026

🚗⚡ Another EV Charging Point Successfully Installed! ⚡🚗

Today we completed the installation and commissioning of a commercial EV charging point, providing a reliable and convenient charging solution for electric vehicle users.

✅ EV charger installation completed
✅ Safe electrical connections and protection devices verified
✅ Inspection, testing & commissioning carried out
✅ Full operational checks completed
✅ Ready for everyday use

At PowerOn Engineering Limited, we take pride in delivering professional electrical installations that meet current regulations and provide long-term reliability for our customers.

Whether you need a domestic EV charger, commercial charging point, consumer unit upgrade, fault finding, or general electrical work, we’re here to help.

📍 Covering London, Kent & surrounding areas
📞 07511 635009
📧 [email protected]
🌐 PowerOn-Electrician.co.uk

✅ Another Air Conditioning Supply Installation Completed! ✅Today we completed a dedicated power supply installation for ...
31/05/2026

✅ Another Air Conditioning Supply Installation Completed! ✅

Today we completed a dedicated power supply installation for a new air conditioning system, including:

🔹 New dedicated AC circuit installation
🔹 External isolators fitted for safe maintenance
🔹 Full testing and inspection carried out
🔹 Electrical Installation Certificate issued
🔹 AC unit commissioned and tested
🔹 Final operational checks completed

Everything tested to BS 7671 requirements and left fully operational.

The customer was very happy with the quality of the installation and has already booked us back to rectify several other electrical issues identified within the property. 👌

If you’re looking for a reliable electrician for AC supplies, fault finding, consumer unit upgrades, lighting, power or electrical inspections, get in touch.

📞 07511 635009
📧 [email protected]
🌐 PowerOn-Electrician.co.uk

29/05/2026

⭐️⭐️⭐️⭐️⭐️

Post a review to our profile on Google

Address

London
DA17

Alerts

Be the first to know and let us send you an email when PowerOn Engineering LTD posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to PowerOn Engineering LTD:

Shortcuts

Sponsored

Share

Category