17/01/2020
Here’s how an Anglian Air Source Servicing professional engineer keeps your heat pump in optimum condition and running efficiently saving you money.
Change or clean the filters. Airflow is the number one factor in air source heat pump efficiency, and heat pumps are even more dependent upon free flow of system air through clean filters.
Manufacturer’s recommendations call for filter cleaning or changes every twelve months also if required change the plasma air quality filter.
Inspect the indoor coil for dirt buildup or mould. These can degrade efficiency and cause problems like coil icing and water damage from melting ice. An Anglain Air Source Servicing engineer has solvents designed for coil cleaning.
Clean the condensate pan under the air handler and make sure the drain system is open. If evidence of growing algae or mould is found that can plug drain lines, the technician will clean the system with alagaecide.
Clear encroaching vegetation around the outside unit to maintain free flow of air. Clean the outdoor coil and remove leaves, grass clippings and other debris from the interior.
Verify the proper level of system refrigerant charge and of all other fluids .
We check operation of all components including heat exchanger and strainers, check calibration of sensors, check and test safety devices
Inspect & report on pipework, assess running time, starts & back-up, check integrity & safety of electrical connections and unvented hot water cylinder safety checks including pipes and safety valves.
We also clean the outdoor unit cover protecting the case from discolouring and weather damage.
We provide you with a service certificate confirming all service works carried out.