After 12 years or so of fitting Viessmann boilers, I finally got the opportunity to fit a Vitodens 200-w system boiler. ...
19/07/2023

After 12 years or so of fitting Viessmann boilers, I finally got the opportunity to fit a Vitodens 200-w system boiler. Another first for me was the use a plate heat exchanger to separate the sealed boiler side from the open vent radiator circuit. New 200 litre unvented cylinder replaced the open vent hot water cylinder. The boiler is controlled by weather compensation making it as efficient as possible. The 7” touchscreen can located at the bottom or the top (like in the picture) of the boiler.

The importance of boiler servicing. The burner chamber of this Worcester Bosch system boiler was blocked solid with carb...
06/10/2022

The importance of boiler servicing. The burner chamber of this Worcester Bosch system boiler was blocked solid with carbon - took a fair amount of effort to get it clean for efficient operation.

20/08/2022

Currently closed for Summer break. Re-open w/c 12th September 2022.

Last one before Christmas. Out with a leaking Ideal Logic and in with a nice new Viessmann 100-w 30kw Combi.  These boil...
16/12/2021

Last one before Christmas. Out with a leaking Ideal Logic and in with a nice new Viessmann 100-w 30kw Combi. These boilers are awesome.

Called out to a L2 fault on an Idea Logic boiler. Had a good idea of the cause of the fault before even opening up the c...
18/11/2021

Called out to a L2 fault on an Idea Logic boiler. Had a good idea of the cause of the fault before even opening up the case, but was not expecting to find a copper elbow in the bottom of the combustion chamber. Found many insects but nothing like this. Luckily, the condense has not corroded through the case which would have meant a new boiler.

22/10/2021

Milwaukee 12v compressor makes light work of recharging expansion vessels. Shame the installer of this cylinder decided to put it in front of the mains stop c**k and the cold water combination valve (somewhere in the darkness of the corner). Managed to get to stop c**k but the pressure relief of the valve is running water. Customer asked what’s the answer? The answer is drain the heating, the cylinder, disconnect it and move it out of the way. Replumb the stopc**k and the cold water valve in a space that Is easily accessible for operation and servicing.

Having to change an immersion on an unvented cylinder. Very poor design when the immersion is lower than the cold inlet ...
13/10/2021

Having to change an immersion on an unvented cylinder. Very poor design when the immersion is lower than the cold inlet drain off. Will have to siphon off the difference and hope the water level is lower than the immersion when I crack it open. 🙏

Just completed the annual service and 5 years on, this Viessmann 100-W combi is running as efficiently as the day I inst...
10/02/2020

Just completed the annual service and 5 years on, this Viessmann 100-W combi is running as efficiently as the day I installed it.

Work in progress. Back boiler and open vent cylinder out, 30kw Viessmann 100-W combi in. This airing cupboard really is ...
19/12/2018

Work in progress. Back boiler and open vent cylinder out, 30kw Viessmann 100-W combi in. This airing cupboard really is snug.😂

Little boiler change I completed this week. Took out an Ideal combi boiler which was corroding, failing to deliver hot w...
13/12/2018

Little boiler change I completed this week. Took out an Ideal combi boiler which was corroding, failing to deliver hot water and had no room thermosat. Replaced it with a Viessmann 100-W 35kw combi complete with a Magnaclean, Combimate (a real must to combat scale when you live in Ottery) and an EPH Combipack 4 programmable room thermostat which features Optimum Start Control and is Boiler Plus compliant. The gas pipe run was increased to 28mm copper to within 1.5m of the boiler location. On commissioning, the boiler runs at 65 degrees with a return temperature of 50 Degrees, keeping it condensing efficiently.
All materials supplied by Total Plumbing Supplies Ltd.

Address

22 Oak Close
Ottery Saint Mary
EX111BB

Telephone

+447887955697

Website

Alerts

Be the first to know and let us send you an email when Stephen Gill Plumbing & Heating posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Stephen Gill Plumbing & Heating:

Share