Davies Electrical

Davies Electrical Your local & independent electrician based in Powick.

We cover Malvern, Worcester & the surrounding areas, working to a high & professional standard with all the work we carry out.

🔌 Garage sockets 🔌Here is a job we completed the other week…The customer requested a couple of sockets within their gara...
07/02/2026

🔌 Garage sockets 🔌

Here is a job we completed the other week…

The customer requested a couple of sockets within their garage for equipment they are using along with a small heater.

We decided to keep this installation separate from the existing installation… why ? We wanted the new circuit to have type ‘A’ RCD protection & surge protection.
The mains supply along with the original consumer unit was located under the stairs, therefore we managed to obtain the above whilst keeping up to regulations with a metal consumer unit.

🤔 Not enough socket & needing more ?
🤔 Sockets looking out dated ?

⭐ New installations ✅
⭐ Additions ✅
⭐ Alterations ✅
⭐ Heating controls ✅
⭐ Consumer unit upgrades ✅
⭐ Testing ✅
⭐ Extensions ✅
⭐ Full & partial rewires ✅
⭐ Internal & External lighting ✅
⭐ NICEIC Registered Electrician ✅

📧 📞 Feel free to get in contact with us in regards to any electrical work large or small.

💡Consumer unit upgrade💡At the start of the year we were asked to carry out an electrical installation condition report (...
24/01/2026

💡Consumer unit upgrade💡

At the start of the year we were asked to carry out an electrical installation condition report (EICR) on this property.

Upon seeing the consumer unit, it appeared the RCD had been removed & therefore questions were raised.

A previous Electrican could not find/locate a fault & therefore removed the safety device (RCD) to stop nuisance tripping (and ultimately this is why we were asked to carry out the EICR).

All circuits were tested for clarity, identification & condition.
The installation was deemed as unsatisfactory & therefore a report along with a quotation was given for the rectification of the observations made.

The end result was a consumer unit change, rectification of all code 2’s and the changing of smoke alarms (of which were 25 years old).

🤔 Is your electrical installation looking dated ?
🤔 Do you have concerns about your wiring ?
🤔 Has the next recommended test date on your consumer unit expired ?

⭐ New installations ✅
⭐ Additions ✅
⭐ Alterations ✅
⭐ Heating controls ✅
⭐ Consumer unit upgrades ✅
⭐ Testing ✅
⭐ Extensions ✅
⭐ Full & partial rewires ✅
⭐ Internal & External lighting ✅
⭐ NICEIC Registered Electrician ✅

📧 📞 Feel free to get in contact with us in regards to any electrical work large or small.

Wishing all a very Merry Christmas 🎄 & a happy new year ❄️ ⛄️ 🎅🏻
24/12/2025

Wishing all a very Merry Christmas 🎄 & a happy new year ❄️ ⛄️ 🎅🏻

22/11/2025
21/05/2025
Wishing all my customers, followers & friends a very Merry Christmas & a Happy New Year 🎄 🎅🏻 Ollie at Davies Electrical.
25/12/2024

Wishing all my customers, followers & friends a very Merry Christmas & a Happy New Year 🎄 🎅🏻
Ollie at Davies Electrical.

We missed this one 😬 here you go….⏮️🔄 ✅ Rewire 3 of 3 complete ✅ 🔄⏮️ Possibly the last full Rewire of 2024 ?A great plas...
17/11/2024

We missed this one 😬 here you go….

⏮️🔄 ✅ Rewire 3 of 3 complete ✅ 🔄⏮️

Possibly the last full Rewire of 2024 ?
A great plasterer we know passed our number onto this customer & they really wanted a full Rewire (and rightly so)….

Upon removing accessories we found the dreaded ‘green goo’, multiple spurs & lots f hidden junction box’s (just to mention a few things).

The customers had also requested for the future provisions of circuits such as: Rear extension, side utility & potential loft conversion.

All completed & now ready for plastering, this is another happy customer & another job ticked off the list.

⚪️ accessories.

🟢 Optical Smoke Alarms

🟢 Crabtree consumer unit with ⬇️

🟢 Type 2 SPD (Surge Protection Device).
🟢🟢 Type ‘A’ RCBO’s.
🟢🟢🟢 Spare Ways - For future use.
🟢🟢🟢🟢Identification of circuits (Ring mains & smoke alarm circuit).
🟢🟢🟢🟢🟢Sealing arrangements where required - entry points.

⬆️ This comes as standard with all rewires for many reasons such as regulations & clarity.

Once again, another MAHOOSIVE shoutout to Mr Preston of for the graft & company (always a pleasure with this lad)!

⭐️ New installations ✅
⭐️ Additions ✅
⭐️ Alterations ✅
⭐️ Heating controls ✅
⭐️ Consumer unit upgrades ✅
⭐️ Testing ✅
⭐️ Extensions ✅
⭐️ Full & partial rewires ✅
⭐️ Internal & External lighting ✅
⭐️ NICEIC Registered Electrician ✅

📞 📧 Feel free to get in contact with us in regards to any electrical work

⏮️🔄 ✅ Rewire 2 of 3 complete ✅ 🔄⏮️ We attended to do a survey on this property & found no earth within lighting cables, ...
30/09/2024

⏮️🔄 ✅ Rewire 2 of 3 complete ✅ 🔄⏮️

We attended to do a survey on this property & found no earth within lighting cables, 3036 rewireable consumer unit…. along with very outdated sockets & switches.
There was also 1 socket in each room (not ideal with today’s demands).
So another job where the installation was long overdue a full rewire.
Another job complete with the customers refuelling us with Coffee ☕️ & biscuits 🍪 😁.

The request on this property as it is 2x semi detached bungalows was to install a Sub Main to eventually have 1 meter.
This is all ready for the future works to be carried out.

⚪️ accessories.

🟢 Optical Smoke Alarms

🟢 Crabtree consumer unit with ⬇️

🟢 Type 2 SPD (Surge Protection Device).
🟢🟢 Type ‘A’ RCBO’s.
🟢🟢🟢 Spare Ways - For future use.
🟢🟢🟢🟢Identification of circuits (Ring mains & smoke alarm circuit).
🟢🟢🟢🟢🟢Sealing arrangements where required - entry points.

⬆️ This comes as standard with all rewires for many reasons such as regulations & clarity.

⭐️ New installations ✅
⭐️ Additions ✅
⭐️ Alterations ✅
⭐️ Heating controls ✅
⭐️ Consumer unit upgrades ✅
⭐️ Testing ✅
⭐️ Extensions ✅
⭐️ Full & partial rewires ✅
⭐️ Internal & External lighting ✅
⭐️ NICEIC Registered Electrician ✅

📞 📧 Feel free to get in contact with us in regards to any electrical work


⏮️🔄 ✅ Rewire 1 of 3 complete ✅ 🔄⏮️ We go asked to quote for some additional lights & quickly found after a quick survey ...
13/09/2024

⏮️🔄 ✅ Rewire 1 of 3 complete ✅ 🔄⏮️

We go asked to quote for some additional lights & quickly found after a quick survey that the property was long overdue a full rewire.
This job has some more time consuming areas such as the flat roof which limited access.
We were lucky on this rewire that it was plastered straight after second fix.
All went as planned whilst the customers moved out & today we handed it over all second fixed & plastered (ready for the decorating to commence)!.
A massive shout out to for the push on this one (always a pleasure to have this lad help me!).

⚪️ accessories.

🔴🟢 Heat & Optical Smoke Alarms

⚫️ V50 Downlight’s with white bezels.

🔵 consumer unit with ⬇️

🔵 Surge Protection.
🔵 Type ‘A’ RCBO’s.
🔵 Bi-directional RCBO for solar P.V
🔵 Spare Ways - For future use.
🔵 Identification of circuits (Ring mains & smoke alarm circuit).
🔵 Sealing arrangements where required - entry points.

⬆️ This comes as standard with all rewires for many reasons such as regulations & clarity.

⭐️ New installations ✅
⭐️ Additions ✅
⭐️ Alterations ✅
⭐️ Heating controls ✅
⭐️ Consumer unit upgrades ✅
⭐️ Testing ✅
⭐️ Extensions ✅
⭐️ Full & partial rewires ✅
⭐️ Internal & External lighting ✅
⭐️ NICEIC Registered Electrician ✅

📞 📧 Feel free to get in contact with us in regards to any electrical work


🔵⚪️Consumer Unit Change⚪️🔵🔴 This is a recent consumer unit change we undertook. Due to the initial pre-test/EICR we carr...
16/06/2024

🔵⚪️Consumer Unit Change⚪️🔵🔴

This is a recent consumer unit change we undertook.
Due to the initial pre-test/EICR we carried out we discovered a few issues & after the following we decided to upgrade:

❌Lack of RCD protection for circuits
❌ No spare ways for expansion/new circuits.
❌ High & inconsistent readings

We now have replaced this & have the following in place:

🔵 Surge Protection.
🔵 Type ‘A’ RCBO’s.
🔵 Spare Ways - For future use.
🔵 Identification of circuits.
🔵 Sealing arrangements where required - entry points.

If you want to know more or would simply like your installation checked contact us & we would be happy to help & assist.

⭐️ New installations ✅
⭐️ Additions ✅
⭐️ Alterations ✅
⭐️ Heating controls ✅
⭐️ Consumer unit upgrades ✅
⭐️ Testing ✅
⭐️ Extensions ✅
⭐️ Full & partial rewires ✅
⭐️ Internal & External lighting ✅
⭐️ NICEIC Registered Electrician ✅

📞 📧 Feel free to get in contact with us in regards to any electrical work

Something A Little Different! 👀 The other week We Installed A Fully Electric Boiler & Unvented Cylinder In The Centre Of...
16/06/2024

Something A Little Different! 👀
The other week We Installed A Fully Electric Boiler & Unvented Cylinder In The Centre Of A Flat Due To A Failed Shared Chimney Duct.
This was a 12kW system boiler & due to the property being supplied by a 60A fuse, we had to fully range rate the system down to 6kW (28A).
We also added a for the opentherm controls.
Again something a little different but always a pleasure for the lads at &
This also includes a separate consumer unit for the installation with Surge protection & RCD protection for circuits installed.

🔵 DHW Zone valve
🔴 CH Zone valve
⚪️ Immersion Heater
🔵 Cylinder stat
🔴 Smart heating controls
⚪️ 63A Rotary isolator

⚡️ ⚡️

Address

Powick

Opening Hours

Monday 8am - 4:30pm
Tuesday 8am - 4:30pm
Wednesday 8am - 4:30pm
Thursday 8am - 4:30pm
Friday 8am - 4:30pm

Website

Alerts

Be the first to know and let us send you an email when Davies Electrical posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Davies Electrical:

Share

Category