Huge saw had its spinal cord mangled....... We sorted it out and managed to clear the faults on the screen and got this ...
12/12/2023

Huge saw had its spinal cord mangled....... We sorted it out and managed to clear the faults on the screen and got this BALLbad boy earning its crust again.

New job this week....... Can anyone guess who/where we are rescuing this time around????
12/12/2023

New job this week....... Can anyone guess who/where we are rescuing this time around????

20kw BN Thermic installed recently..... Very juicy......
12/12/2023

20kw BN Thermic installed recently..... Very juicy......

New job day!!!!
19/11/2023

New job day!!!!

If your going to use anything it's always going to be victron! Bravo boys 👏 👏
13/11/2023

If your going to use anything it's always going to be victron! Bravo boys 👏 👏

10KW Off-grid system.

Our customer wanted another charge controller and 20 panels adding to their existing off-grid system.

New job start...............
13/07/2023

New job start...............

We were asked by one of our   partners to go and look at a job which had been done by another contractor (we won't menti...
17/06/2023

We were asked by one of our partners to go and look at a job which had been done by another contractor (we won't mention their name) because they had major safety concerns and they had walked off site because as they said to me via an email "it's not right" so we went and did a site survey and this is some of the things we found. Examples like the kitchen DB was fed in a 6mm 3 core SWA which had 10 32amp circuits connected via RCBO"s 😳, no fire detection anywhere. Massive phase in balances and a high Ze in the pool plant room. No earth sleeving anywhere, incorrect cables installed and tray work installed and cut by blind men plus it was mounted to 3x2 timber! To much to list tbh. Would you run a mile or be good guys and offer the client an olive branch to get it to a compliant stage? It's shocks us how this type of thing can happen and why nothing was said before this stage.....Clients are really nice people a truly don't deserve this.
Thoughts people
😤 😔

Another successful boiler house finished! Fresh water comes from a well through the blue tanks then pumped through the l...
19/05/2023

Another successful boiler house finished! Fresh water comes from a well through the blue tanks then pumped through the lodge, new controls wired in as the original had never worked as they had been damaged and had issues with eddy currents causing mayhem. Honeywell controls have now been installed and working as it should be! Clients over the moon!

Address

Unit E, Ashton Business Park
Preston
PR22AX

Opening Hours

Monday 8am - 5pm
Tuesday 8am - 5pm
Wednesday 8am - 5pm
Thursday 8am - 5pm
Friday 8am - 5pm

Telephone

+447985105853

Website

Alerts

Be the first to know and let us send you an email when Prestons Electrical ltd posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Prestons Electrical ltd:

Share

Category