The damage rodents cause can be substantial and often unseen, leading to nuisance tripping and potentially dangerous exp...
05/04/2022

The damage rodents cause can be substantial and often unseen, leading to nuisance tripping and potentially dangerous exposed cabling

13/04/2019
Few more photos of a recent job and a call it to a shower that had been tripping on and off until it finally gave up
22/01/2019

Few more photos of a recent job and a call it to a shower that had been tripping on and off until it finally gave up

First fix for rewire under way
16/11/2018

First fix for rewire under way

Pictures of ring main rewired, and call out to premises with a smoking main switch goes to show the importance of regula...
09/11/2018

Pictures of ring main rewired, and call out to premises with a smoking main switch goes to show the importance of regular maintenance on electrical systems

Small utility and shower room,Shower in main house fed straight from 63amp rcd! At least there will be no nuisance trip ...
24/10/2018

Small utility and shower room,
Shower in main house fed straight from 63amp rcd! At least there will be no nuisance trip from drawing too much power

New sign lights wired up for Body Zone Gym
16/10/2018

New sign lights wired up for Body Zone Gym

Asked to add a few sockets found a few junction boxes and bits under the floor and that the whole house and kitchen were...
04/10/2018

Asked to add a few sockets found a few junction boxes and bits under the floor and that the whole house and kitchen were on one ring main/circuit so not enough for a modern house with all that is plugged in nowadays. So work commences adding two new ring mains. One for upstairs one for downstairs perfect time to do it though before the new carpets etc go down so always worth getting electrical checked prior as it would have made a mess to carry out after.

Friday morning fusebox change no main earth cable to old board, old night storage board converted to mains board via 6mm...
21/09/2018

Friday morning fusebox change no main earth cable to old board, old night storage board converted to mains board via 6mm off of mains switch and earth cable snipped off and no bond to the gas meter 😦 previous electrician obviously didn’t think there was a need for them