 still struggling with short neutral cables in your RCBOs, highlighted this many times now and have been told they are l...
05/02/2026

still struggling with short neutral cables in your RCBOs, highlighted this many times now and have been told they are longer but none I’ve ever had?!

Swapping out an old technology Helvar commercial dimming system at a church with a new LED compatible unit. Had to diver...
16/11/2024

Swapping out an old technology Helvar commercial dimming system at a church with a new LED compatible unit. Had to divert multiple MICC or Pyro cables and then extend into the new panel especially tricky as the panel is three phase and some circuits had shared neutrals in the multicore Pyros with potentially disastrous results if wrongly connected. All went to plan and worked well on the LED lamps around the auditorium. Just some DALI programming to do.

LED lighting upgrade, 140 old 54W T5 fluorescents out, new 30W DALI LED panels In
02/06/2024

LED lighting upgrade, 140 old 54W T5 fluorescents out, new 30W DALI LED panels In

Fun day making space in an 800A busbar chamber for 4 x 400A tap offs ready for the panel board installation next Saturda...
19/11/2023

Fun day making space in an 800A busbar chamber for 4 x 400A tap offs ready for the panel board installation next Saturday- bit of trunking to finish in the week and 185mm singles to install

When you get 60M of 25mm 5c SWA and the cable route changes without anyone telling you so  you fashion a cable joint pit...
25/02/2023

When you get 60M of 25mm 5c SWA and the cable route changes without anyone telling you so you fashion a cable joint pit to keep the duct run continuous.

Bit of old MEM now Eaton electrical switchgear, all still in service. The old PFC capacitors have blown up so replacemen...
02/04/2022

Bit of old MEM now Eaton electrical switchgear, all still in service. The old PFC capacitors have blown up so replacements needed.

Started a small mobile phone site last week in central London, due to site restrictions it’s a 4.00AM start on site but ...
11/10/2021

Started a small mobile phone site last week in central London, due to site restrictions it’s a 4.00AM start on site but finish at 12 lunchtime. Carrying on this week.

Little tidy up and new DB at Ware Bowls Club, sorting out a small fault on the irrigation system too.
27/06/2021

Little tidy up and new DB at Ware Bowls Club, sorting out a small fault on the irrigation system too.

Thank you  for the Wiska 308 spikes, perfect fir a light garden lighting job. Always use  EC308 for the Armour continuit...
26/06/2021

Thank you for the Wiska 308 spikes, perfect fir a light garden lighting job. Always use EC308 for the Armour continuity on SWA cables, NOT stuffing glands which seem to be a thing for people with no idea.

Finally started on the panel board swap, out with the old. Have to temporary power both panel during the swap as we are ...
15/06/2021

Finally started on the panel board swap, out with the old. Have to temporary power both panel during the swap as we are only allowed to shut power off for a limited time each day. Old LEB CT metering chamber will be gone soon.

07/06/2021

Think we found the cause of the low insulation resistance reading

First fix nearly complete  distribution board and trunking mounted yesterday.    📷
25/03/2021

First fix nearly complete distribution board and trunking mounted yesterday. 📷