An EPC Company -11/66/220 KV Installation # Testing and Commissioning of Transformers # Er****on of HT/LT & Sub Stn. || HVDS System # Street Light work & High Mast # Trenchless # Electrification # Redevelopment of Yard # Tower Installation # Cable Laying|

This figure offers a detailed explanation of capacity and load calculations for distribution transformers, specifically ...
27/01/2026

This figure offers a detailed explanation of capacity and load calculations for distribution transformers, specifically those ranging from 33/11 kV to 11/0,415 kV.

👍 R E Engineers


Electrical    ゚viralシfypシ゚viralシalシ
27/01/2026

Electrical

゚viralシfypシ゚viralシalシ

A to z Electrical working            ゚viralシfypシ゚viralシalシ
27/01/2026

A to z Electrical working

゚viralシfypシ゚viralシalシ

Water Project    ゚viralシfypシ゚viralシalシ
27/01/2026

Water Project


゚viralシfypシ゚viralシalシ

Transformer load calculation                                   ゚viralシfypシ゚viralシalシ
17/01/2026

Transformer load calculation


゚viralシfypシ゚viralシalシ

HT-Panel Full Testing Checklist Before Energized ⚡👇  ゚viralシfypシ゚viralシalシ
17/01/2026

HT-Panel Full Testing Checklist
Before Energized ⚡👇
゚viralシfypシ゚viralシalシ

Transformer Inspection & Maintenance Checklist ⚡👇 Save and Share 🙏              ゚viralシfypシ゚viralシalシ
17/01/2026

Transformer Inspection & Maintenance Checklist ⚡👇
Save and Share 🙏
゚viralシfypシ゚viralシalシ

Motor KW Rating, Current, Cable and MCB TABLE         ゚viralシfypシ゚viralシalシ                    #
14/01/2026

Motor KW Rating, Current, Cable and MCB TABLE

゚viralシfypシ゚viralシalシ #

â—Źâ—Źâ—ŹA GIS substation (Gas-Insulated Substation) works by using SF, gas (sulfur hexafluoride) as the main insulating and a...
14/01/2026

â—Źâ—Źâ—ŹA GIS substation
(Gas-Insulated Substation) works by using SF, gas (sulfur hexafluoride) as the main insulating and arc-quenching medium instead of air. Because SF, has excellent insulation strength, all high-voltage parts are enclosed inside sealed metal compartments, making the substation compact, safe, and reliable.

1)Incoming Transmission Line

Power enters the GIS through bushings or gas-to-air terminations

The voltage can be 66 kV, 132 kV, 220 kV, 400 kV, or higher

2) Busbars
Conductors carrying power to different bays
Enclosed in SF-filled metal tubes
Insulated and protected from dust, moisture, and pollution

3) Disconnector (Isolator)

Provides visible isolation for maintenance
Operates only when no load current is flowing
Ensures safety by physically separating sections

4) Circuit Breaker (CB)

The most critical part Opens/closes the circuit during:
Normal switching
Fault conditions
Fault conditions

✅️When contacts separate:
An arc forms
SF, gas rapidly extinguishes the arc
Protects equipment and system stability

5)Current Transformer (CT)

Measures current
Sends scaled-down signals to:
Protection relays
Meters

6)Voltage Transformer (VT/PT)
Measures voltage and
Used for:
Metering
rotection
Control systems

7)Earthing Switch

Grounds isolated sections
Removes trapped charges
Ensures safe maintenance

8)Outgoing Feeder / Transformer

Power exits the GIS to:
Power transformers
Distribution lines

â– â– â– Basic Principle

In a GIS substation:

Current flows through conductors enclosed in metal chambers SF, gas insulates live parts and extinguishes arcs during switching
Equipment like circuit breakers, disconnectors, and busbars are modular and enclosed







゚viralシfypシ゚viralシalシ

PT Classes
14/01/2026

PT Classes

CC bracking work
13/01/2026

CC bracking work

Electrical Formulas & Concepts
23/12/2025

Electrical Formulas & Concepts

Address

Noida
201304

Alerts

Be the first to know and let us send you an email when R E Engineers posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share

Category