JAI MAA AMBEY POWER

JAI MAA AMBEY POWER We have pleasure to introduce ourselves as a proficient operation and maintenance company in the field of Power Generation services.

We are in the energy business particularly in the field of Operation & Maintenance Services with a team of well experience Company Profile
We have pleasure to introduce ourselves as a proficient operation and maintenance company in the field of Power Generation services. We are in the energy business particularly in the field of Operation & Maintenance Services with a team of well experienced O&M

Engineers. The company has an impressive track record for serving its customers with unfaltering services. This could have been possible because of our Proficiency & specialization acquired by means of Perseverance & Devotion to our profession and with the support of our team of Technocrats who constitute the back bone of our organization. We stress on exploring new ideas and attempting breaks through processes and services
The Company
The Company Jai Maa Ambey Power (JMAP) is a group of well Known technocrats. The Company is consists of professionals engaged in Operation & maintenance and Er****on and commissioning of Power Plants. The JMAP is working as a complete solution provider to the power plants. The company has registered its presence and is proud to have a list of satisfied clients from the field of power generation,
The Range of services offered by the company are:
• Operation and Maintenance of Thermal/Bio-Mass Based power plant.
• Power Plant Startup/Commissioning Services
• Pre-commissioning and commissioning assistance.
• Providing Expertise Man Power for Power Plants O&M.
• Total Engineering from concept to commissioning which include planning, engineering, Project Development, procurement, project management, inspection & expediting, construction & commissioning and post commissioning advisory services.
• Maintenance Services for distribution Systems, Substations & Switchgear.
• Shutdown Services. The strength of JMAP lies in battery of highly experienced professionals from the field of Power supported by a highly motivated & dedicated Team of young Engineers. The experts at JMAP have worked in the power sector for more than 35 years and have executed number of Thermal, Gas and Biomass based projects with WHRB,AFBC,CFBC,Liquor Fired and Travelling Grate Boiler from concept to commissioning in different type of industries like Paper Industries, Sugar Industries, Textile Industries, Cement Industries, Oil and refineries, Steel Industries etc. Clients Values

We clearly understand our value of the customer is only measured by achievement of their needs. Each customer has unique needs and our first task is to understand them and establish goals that meet each need. Each employee will clearly understand the importance in achieving those goals. The ability to meet the needs of our customer entirely on the quality of the individuals performing work combined with a well-organized action plan. We place extreme importance on employee selection, training, team building and safety and motivational programs, assure the quality of personnel and that they work as a team. Our action plans are pre- established and proven, but are continuously evolving as we find more cost effective ways to complete our tasks

The O & M staff will be self-sufficient in completing frequently occurring activities such as routine operations, light equipment repairs, preventive maintenance, reporting, payroll and purchasing. For the infrequent or highly specialized activities such as major equipment overhauls, a separate major overhaul team will be established and a portion of the planned outage if necessitated by scheduled constraints. We do all types of documentation work for plant performance enhancement and track records are used to analyze the improvement of plant performance and to calculate the Fuel consumption, Water uses and Discharge, Electricity generation and consumption. We also utilize a central filling system, which permits all documentation and records to be logically segregated, stored and retrieved. The plant administrative follicles and procedures manual include a section, which describes the detailed development and maintenance procedure for records management.

happy independence day
15/08/2015

happy independence day

chatt puja ki hardik subhkamnayen
29/10/2014

chatt puja ki hardik subhkamnayen

18/10/2014
M/s Ambalika Sugars Pvt. Ltd. Rashin, (Maharashtra) Electrical Work in Progress
15/09/2014

M/s Ambalika Sugars Pvt. Ltd. Rashin, (Maharashtra) Electrical Work in Progress

M/s Sar Senapati Santaji Ghorpade sugar Factory Limited Electrical Work in progress......
21/07/2014

M/s Sar Senapati Santaji Ghorpade sugar Factory Limited Electrical Work in progress......

17/07/2014

URGENT REQUIREMENT FOR ELECTRICAL ENGINEER, FITTER, WELDER, AND ELECTRICIAN FOR KOLHAPUR SITE ER****ON WORK THOSE INTERESTED PLEASE CALL AT +91-7781013695

New Opening for power Plant
01/02/2014

New Opening for power Plant

HAPPY REPUBLIC DAY
26/01/2014

HAPPY REPUBLIC DAY

15/01/2014

We are currently looking for three Safety Engineers having at least two years of experience in relative field for our er****on sites in India. Those who are interested send your resume including with your current CTC and Expected CTC at [email protected] or [email protected] as soon as possible as the recruitment process is going on. for any query feel free to mail us at [email protected]

09/01/2014

Determining the Loss On Ignition (L.O.I.)

Weigh the empty ceramic crucible exactly and note the mass (n1) on the L.O.I. form. Slowly add the powder with the spatula and note the total mass (n2 = ceramic crucible + sample powder). No exactly mass of sample is necessary but to determine it with an accuracy of 0.1 mg (0.0001g).
Weigh the crucible cold, always 10 minutes after removing it from the oven. Room temperature is reached in the crucible after ca. 5 minutes. If the crucible is still too hot, the air in the closed weighing chamber would be heated up, expanding and press on the scale. In experiments performed in this lab, it became obvious that the error due to adsorption of air moisture becomes negligible after 10 minutes. After 15 to 20 minutes though, recarbonatisation plays an increasingly significant role. Note its total mass (n3) and calculate the L.O.I. using this formula:
Formula for L.O.I. :
L.O.I. (weight %) = 100 x ( (n2-n3) / (n2-n1) )

The L.O.I. is made of contributions from:
Volatile compounds :
H2O+, CO2, F, Cl, S; in parts also K, Na (if heated for too long);
Added compounds :
O2 (oxidation, e.g. FeO to Fe2O3), later CO2 (CaO to CaCO3).
NOTE: For later interpretation of the results of measurement:
Due to the escape of volatiles, there will be an increase of mass among all other oxides. By oxidizing FeO to Fe2O3, the value of Fe2O3 total increases but all other oxides will be mass-reduced. These changes in concentration are considered in the calculation of the analysis data.
Rehomogenization
The burned off sample has to be rehomogenized in an agate mortar until the compound has a uniform colour. Depending on rock chemistry, at 1050° C and following cooling, a sintering, partial glass formation, or partial crystallization might occur. The grinding of the sinter optimizes the homogeneity and reduces the analytical errors.

Address

House No 63
Patna
800001

Alerts

Be the first to know and let us send you an email when JAI MAA AMBEY POWER posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share

Category