23/10/2020
FRIDAY REPORT.
Today, just like any other day, we were out in the field attending to our clients call.
Problem reported
1. Instant showers not working.
2. Initial installation of Solar Water Heater accrued very high power bills, but eventually the tank burst.
In order to give a professional report and solution, one of our engineers visited the site.
Finding.
1. Solar Water heater Tank had burst as reported. This might be due to malfunctioned auto pressure release valve. This types had preheated water settings which uses mains and this was the cause for high power bills.
2. Due to the malfunctioning hot water system, the client opted for instant showers. He however did wrong design ( quick fix solutions). The supply was tapped from socket supply using a flex 2.5 sq mm 3core cable. Its results are evident. ( Sheathing burnt over time, frequent tripping of Circuit breakers, frequently malfunctioning heaters)
We have offered our solutions
1. Replace the Solar water heater and do right setting on the controller pre heating settings.
2. If above is not achievable, redesign the instant shower power circuit to guarantee RELIABILITY, DURABILITY and COST EFFECTIVENESS.
The ball in now on the clients side.
At Lakiy Electrical and Engineering LTD we value quality. Reach out to us for electrical installation works. Our numbers are 0721118979.