MA Hafiz Wiring Service

MA Hafiz Wiring Service Wiring Service - Single Phase Wiring, Troubleshooting Electric Problem, Additional/new wiring

Troubleshooting wiring tripFinding: Faulty on 2 pole MCB (Main switch)Site: Tanjong Malim
01/12/2025

Troubleshooting wiring trip

Finding: Faulty on 2 pole MCB (Main switch)

Site: Tanjong Malim

Each studio room- 1 x meter panel- 1 x Distribution Board (DB)  * 2 pole MCB 40A as Main Switch  * ELCB 40A  * 1 x MCB 2...
23/07/2025

Each studio room
- 1 x meter panel
- 1 x Distribution Board (DB)
* 2 pole MCB 40A as Main Switch
* ELCB 40A
* 1 x MCB 20A for 1hp air conditioner point (2.5mm SIRIM cable)
* 1 x MCB 20A for water heater point (5mm SIRIM cable) with RCCB
* 1 x MCB 20A for 4 nos of 13A SSO (bed area)
* 1 x MCB 20A for 4 nos of 13A SSO (living area)
* 1 x MCB 20A for 4 nos of 13A SSO (pantry)
* 1 x MCB 10A for 3 nos of lamp point & 1 nos of fan point
* 1 x MCB 10A for 3 nos of lamp point
- 1 x 10mm earthing cable connect to copper rod at earthing chamber