BHElectric,Inc

BHElectric,Inc BHElectric,Inc Provides electrical services to Industrial electrical, commercial electrical and municipal water and wastewater electrical.

Provided services, Water and Waste water Maintenance, construction and controls, controls, panels, troubleshooting, repairs, IR, Infrared, lighting, lighting retrofit, industrial construction, industrial maintenance, industrial pm, preventative maintenance, Rigid, OCAL, non corrosive, hazardous environments, Telco, Telecommunication, data center, grounding, testing, critical power, generators, Ats, Automatic Transfer Switch,

Cell site vandalism repairs. Came out really clean. I wonder if it’s bulletproof. I guess will find out soon enough. Thi...
03/14/2025

Cell site vandalism repairs. Came out really clean. I wonder if it’s bulletproof.
I guess will find out soon enough. This is the first site I had to patch and repair bullet holes.

Today we get to recognize Issac for being with BHE for 1 year. He’s doing a great job and progressing every day. I was a...
03/14/2025

Today we get to recognize Issac for being with BHE for 1 year. He’s doing a great job and progressing every day.
I was a little late on the jacket. I think his anniversary was before Christmas.

See anything wrong with this?
02/14/2025

See anything wrong with this?

This broken part is off of 4000 amp fused switch. Cost a customer $49,000.  We determined either a manufacturing flaw in...
02/14/2025

This broken part is off of 4000 amp fused switch. Cost a customer $49,000. We determined either a manufacturing flaw in the part or faulty design that shared the pin. Usually, we can point most failures toward bad maintenance, but if this pin sheared during the opening process because of the impact of the spring and the mechanism slamming against each other then it would be bad design actually doing maintenance, potentially causing the failure.

Never saw a 500 amp breaker before. Apparently square D made this sometime back in their experimental age. Damn teenager...
02/14/2025

Never saw a 500 amp breaker before. Apparently square D made this sometime back in their experimental age. Damn teenagers.

Little bit of vandalism repair. Never made one bulletproof before.
02/14/2025

Little bit of vandalism repair. Never made one bulletproof before.

08/14/2023

Thermal imaging report time. I’ll go through each image and Try to catch electrical failure before it happens.

And so this happened. Not BHE. This contractor was working in 480v gear live installing breaker and shorted it. Tripped ...
10/17/2022

And so this happened. Not BHE. This contractor was working in 480v gear live installing breaker and shorted it. Tripped the fuse in the utility TX. Lucky dude for sure.
Just say no. If it doesn’t look safe if probably isn’t.

Can anyone see what’s wrong with this. An 800a CB was connected to this. Showed up on IR we performed early summer. Good...
09/04/2022

Can anyone see what’s wrong with this. An 800a CB was connected to this.
Showed up on IR we performed early summer. Good catch by my team. Eventually would have been catastrophic.
What the hell was this guy thinking and how the hell was he performing this work.
We talk about the dragon. It refers to the potential catastrophic failure that can be just behind every cover we remove. You will never see the dragon coming just know it’s there and be prepared.

Living the good life.  Saturday on a holiday weekend.
09/04/2022

Living the good life. Saturday on a holiday weekend.