Zap Zach Presents One Doorbell to a Chimer powered by a step down transformer from 120VAC to 16VDC. From the MSP (Main Service Panel) we have 14/2 AWG running from a 15A circuit breaker through the studs and strapped down with staples. Per NEC Article 334.30 (Securing & Strapping) Romex, (NM cable) needs to be supported every 12” from any enclosure: outlet boxes, junction boxes, cabinets or fittings and secured every 4 1/2” intervals. The Romex is aligned in the center of the studs to prevent any damage from the drywall screws once it is mounted to the framing. The Romex terminates into a 4D J-box. It then connects to the Primary leads, 120VAC, on the Step Down Transformer. From the Secondary output, 16VDC, of the Transformer 18/2 AWG (Fire Alarm Cable) is ran through 1/2” EMT with 90 degree stubs and strapped down with 1/2” single hole straps. Also centered on the studs. PER NEC Article 358.30 (A), EMT shall be securely fastened in place at intervals not exceed 10’. In addition each EMT run between termination points shall be securely fastened within 3’ of each outlet box, junction box, device box, cabinet, conduit body or other tubing termination. The Transformers lead (Red Conductor) is then attached to the ‘Transformer Terminal’ on the chime. The Black Conductor is spliced and ran to the Doorbell terminal, thus powering it and allowing the illumination of the Doorbell. From the Doorbell the red wire is then ran to the ‘Front’ designated terminal on the chime. This specific Chime has terminals for ‘Front’ & ‘Back’ doorbells. We only installed one doorbell. Per NEC Article 300.3 (C)(1)): Conductors of Different Systems: 1000 Volts, Nominal, or Less: Conductor of AC and DC circuits, rated 1000 volts, nominal, or less, shall be permitted to occupy the same equipment wiring enclosure, cable, or race-way. All conductor shall have an insulation rating equal to at least the maximum circuit voltage applied to any conductor within the enclosure, cable, or raceway… Thus we are able to combine AC & DC circuits in the same junction box.
NEC Article 300.3 (C)(1)): Conductors of Different Systems: 1000 Volts, Nominal, or Less
NEC Article 334 NM Cable
NEC Article 358 EMT (Electric Metallic Tubing)