Hahn Fire Protection LLC

Hahn Fire Protection LLC Quality installation of fire suppression systems.

Final day of the robotics tournament in Waterloo Canada
03/24/2018

Final day of the robotics tournament in Waterloo Canada

We at Hahn Fire Protection LLC are proud to be part of the First Robotics Canada program!
03/22/2018

We at Hahn Fire Protection LLC are proud to be part of the First Robotics Canada program!

We at Hahn Fire Protection LLC are proud to be part of the First Robotics Canada program!

03/22/2018

Hahn Fire Protection LLC is a proud sponsor of Robotics!!!!!!!

“Teams are loading into the . Event is free to attend. Stop by this weekend and see the robots compete! ”

Insulators often think fire sprinklers are contributing to a failing blower door test. But any contact of foam insulatio...
03/20/2018

Insulators often think fire sprinklers are contributing to a failing blower door test. But any contact of foam insulation with a sprinkler head means the head must be replaced. A major no no!!!!! Had to cut the pipe to get the head out. A very costly mistake.

Insulators often think fire sprinklers are contributing to a failing blower door test. But any contact of foam insulation with a sprinkler head means the head must be replaced. A major no no!!!!! H…

11/26/2017
11/23/2017

Remember keep your tree watered!!!!!

Builders in Baltimore County, your flow tests now cost $796 payable to Baltimore City DPW
11/22/2017

Builders in Baltimore County, your flow tests now cost $796 payable to Baltimore City DPW

[[{"fid":"20883","view_mode":"default","type":"media","fields":{"field_file_image_alt_text[und][0][value]":"open fire hydrant"},"field_deltas":{"1":{"field_file_image_alt_text[und][0][value]":"open

Final Trim out Poplar Ave. These photo’s show how the fire sprinkler system looks when it is finished. The trim plates a...
10/25/2017

Final Trim out Poplar Ave. These photo’s show how the fire sprinkler system looks when it is finished. The trim plates are ty3596 concealed residential plates.

These photo’s show proper spacing off the ceiling fan. The spacing has to be be at least  3 feet off center of fan. Spri...
10/25/2017

These photo’s show proper spacing off the ceiling fan. The spacing has to be be at least 3 feet off center of fan. Sprinkler head can not be under the fan blade.

These photo’s show the proper gap when the sheetrock is done correctly around the sprinkler head. The head type is a tyc...
10/25/2017

These photo’s show the proper gap when the sheetrock is done correctly around the sprinkler head. The head type is a tyco ty3596 concealed head. Do not caulk or foam these gaps between sheetrock and cover plate.

(Continued )Single family house Street Md. Basement Rough in using Blazemaster 1 inch and 3/4 cpvc sprinkler pipe. Sprin...
09/01/2017

(Continued )Single family house Street Md. Basement Rough in using Blazemaster 1 inch and 3/4 cpvc sprinkler pipe. Sprinkler heads installed are Tyco ty3596 Residential Concealed Heads and Tyco ty2234 155 deg pendents. Fire sprinkler source is a 300 gallon water tank with a 1-1/2 Hp booster pump.

Address

PO BOX 1508
Millersville, MD
21108

Opening Hours

Monday 7:30am - 3:30pm