Correct order for using a generator with an inlet box (step by step)
1. Turn OFF utility power at the main breaker
This is the most important step.
Flip the main breaker to OFF
This isolates your house from the grid
➡️ If you skip this, backfeeding is possible.
2. Engage the transfer switch or interlock
Transfer switch: move it from UTILITY to GENERATOR
Interlock kit: slide it so the main breaker cannot be ON
This creates a mechanical lockout so:
Utility and generator cannot be connected at the same time
3. Plug the generator into the inlet box
Use a proper generator cord (never a “suicide cord”)
Ensure:
Correct voltage (120V / 240V)
Correct amperage rating
4. Start the generator (no load)
Let it warm up for 1–2 minutes
Circuit breakers on the generator should still be OFF (if equipped)
This protects the generator from sudden load stress.
5. Turn ON generator breaker
Now power flows:
Generator → inlet box → transfer device → selected circuits
Still no connection to utility lines.
6. Energize circuits gradually
Turn on essential loads first:
• Refrigerator
• Furnace blower
• Well pump
Avoid high-draw appliances all at once
This prevents overloads and voltage drops.
When utility power returns (shutdown order)
This order matters just as much.
- Turn OFF branch circuits
- Turn OFF generator breaker
- Shut down the generator
- Unplug generator from inlet box
- Switch transfer device back to UTILITY
- Turn main breaker back ON
This prevents:
- Generator damage
- Voltage spikes
- Accidental parallel connection