SRP Electric

SRP Electric I have been in business for 25 years doing residential and commercial electrical work. I also specialize in aluminum wiring repair and evaluation.

Specializing in in an interior and exterior lighting design and installation.

07/31/2026
Decon 7 A/C Treatment!Installing a Panasonic select a speed vent today, thoroughly enjoying the attic temperature!! This...
07/31/2026

Decon 7 A/C Treatment!

Installing a Panasonic select a speed vent today, thoroughly enjoying the attic temperature!! This house in Lakewood was built in 1957. Ducted it temporarily into the Attic until it's vented to the roof.
I put it on a Leviton countdown timer, so after every shower it can be set for a certain time and forgotten.

There had been small mold problems around a couple of the air supplies and returns so their A/C Tech guy did a Decon 7 treatment in the ducts and air handler.

I'm troubleshooting my 2018 Focus ST the system that I installed about 6 years ago. I kept the OEM Ford head unit becaus...
07/21/2026

I'm troubleshooting my 2018 Focus ST the system that I installed about 6 years ago. I kept the OEM Ford head unit because I thought it had a quality sound and good tuner. I then ran this speaker line level and puts into a JL Audio Fix 86 sound processor. Then that's runs into a Morel amplifier MPS 5.950, used Morel 6.5 inch component speakersand and JL Audio 8-in ported sub enclosure. It has Sound Matt in all the doors. The FOX 2 circulation fan still works!
I still need to properly mount the Knukoceptz fuse block...
The problem is sometimes the amplifier doesn't come on when the head unit does. It only does it some of the time.

I'm starting with disconnecting the battery to do a hard reset on the head unit and I'm checking the wires connections.

We'd love to sound output and quality sound!

I am posting this because I'm offering custom installs like this.

I worked on a beautiful house in the Hollywood Santa Monica neighborhood in Dallas. This house was built in 1927 and in ...
07/06/2026

I worked on a beautiful house in the Hollywood Santa Monica neighborhood in Dallas. This house was built in 1927 and in a Conservation District. This house is a wonderful Survivor! It was wired with a rare rigid black enamel conduit that can easily have the old cloth wire pulled out a new wiring put in. The entire house is steel lathe plaster.
Original tile Bathroom!

This is a public service warning!! People are putting in too much insulation in their attic!! This makes the house unser...
06/15/2026

This is a public service warning!! People are putting in too much insulation in their attic!! This makes the house unserviceable! Most of the time it is put over loose debris/wood in the Attic. This can be a fire and safety hazard. A lot of people are putting in is this white blow in poly in my pictures most likely because it is inexpensive. If you buy a house with this in it it can hide numerous problems with the HVAC electrical and plumbing.

Every since I have been keeping my tools/multimeters organized like this and Melotough bags I've had no ED issues!
06/04/2026

Every since I have been keeping my tools/multimeters organized like this and Melotough bags I've had no ED issues!

05/22/2026
I just got green tagged, AKA passed the city of Dallas inspection! It is a 320 amp service with two 200 amp Square D QO ...
05/22/2026

I just got green tagged, AKA passed the city of Dallas inspection! It is a 320 amp service with two 200 amp Square D QO 40 space panels. Its disconnect means is a Kohler generator transfer switch. It ohmed out at a .5 ohms!!
We also installed a Grizzlie 100 amp car charger on the stone wall.

Finishing up another sauna! It always baffled me that  somebody in Texas would want one of these but people swear by the...
04/29/2026

Finishing up another sauna! It always baffled me that somebody in Texas would want one of these but people swear by the health benefits!
This is one of the larger ones I've done. It is a 7 KW, most of them are smaller. I ran approximately 105 ft of 6/3 Romex through the Attic. This one I had to build a short with overhead line with two weather heads. I used 6ga quadruplex and a a Square D Homeline eight space sub Rain Tight panel and a weather resistant GFCI outlet with a TAYMAC in use cover.