Victor Valley Electric

Victor Valley Electric We are a service, remodel, and new construction electrical contracting company, that specializes in residential and commercial needs.

Neutrals are required to be terminated individually.  One wire per screw; no double-lugging NEC 408.41
05/03/2026

Neutrals are required to be terminated individually. One wire per screw; no double-lugging NEC 408.41

Landscapers raked the flowerbed, filling the ground junction box.  The sand got wet and caused arcing, which melted the ...
05/03/2026

Landscapers raked the flowerbed, filling the ground junction box. The sand got wet and caused arcing, which melted the wires and caused the outage.

Mobile homes and modular homes have either crossover connectors or crossover junction boxes.  Its not uncommon to have a...
05/03/2026

Mobile homes and modular homes have either crossover connectors or crossover junction boxes. Its not uncommon to have a wire come loose, causing an outage that can't be found easily. ,

A quad 40/40 with  #10 AWG (rated for 30a).  Its safety, general practice and code to match the breaker to the wire gaug...
05/03/2026

A quad 40/40 with #10 AWG (rated for 30a). Its safety, general practice and code to match the breaker to the wire gauge (and vice versa). A water heater and dryer are both 240v, 30a circuits, which requires a.quad 30/30 instead. NEC 240.4(D)

Lights were dim and flickering.  It was a loose neutral burning up in a wirenut!
05/03/2026

Lights were dim and flickering. It was a loose neutral burning up in a wirenut!

Every photo has some type of story...
04/22/2026

Every photo has some type of story...

The quick, "stab-in" wiring method has pro's and con's.  The pro being easy installation, but the con's are multiple.   ...
04/21/2026

The quick, "stab-in" wiring method has pro's and con's. The pro being easy installation, but the con's are multiple. The vibration of AC over time, can causes the wires to pop out of the back of the outlet, or even worse, start to burn.

This is mouse damage on the blue sheathed romex, which ate through to the copper.The white romex is due to an 20a breake...
04/19/2026

This is mouse damage on the blue sheathed romex, which ate through to the copper.
The white romex is due to an 20a breaker on 14 gauge wire (only rated for 15a). The overload melted the wire and could have burned down the house!
*THIS is why you NEVER put a bigger breaker than the wire is rated for. If you need more amperage, then run bigger wire! [NEC 240.4(d)]

Electric water heaters require a non-fused disconnecting means at the unit now [NEC 422.31(b)].  It's a good code additi...
04/18/2026

Electric water heaters require a non-fused disconnecting means at the unit now [NEC 422.31(b)]. It's a good code addition for the safety of plumber and/or electrician.

This is the condition of the breaker for a reported itermittent power issue.  I heard a slight crackling sound and thoug...
04/07/2026

This is the condition of the breaker for a reported itermittent power issue. I heard a slight crackling sound and though the breaker was replaced, it was caught early enough not to have bus damage. If you experience flickering, humming, buzzing, or crackling sounds, get it checked right away!

Address

PO Box 463
Yucca Valley, CA
92284

Opening Hours

Monday 8am - 5pm
Tuesday 8am - 5pm
Wednesday 8am - 5pm
Thursday 8am - 5pm
Friday 8am - 5pm

Alerts

Be the first to know and let us send you an email when Victor Valley Electric posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Victor Valley Electric:

Share

Category