Matty molyneux electrical

Matty molyneux electrical Electrician��
Fully qualified and insured

20/12/2025

As the year draws to a close, and Christmas lights shine bright,
We want to say a huge thank you, for choosing us with all your lights 💡
Your custom's the heartbeat, that keeps our business strong,
We're grateful for your trust, all year long.

Your recommendations and feedback, help me grow and thrive,
And though some may go unnoticed, know they're valued and alive,
We're honored to serve you, and look forward to the new,
With hopes and dreams, and projects anew.

Wishing you a joyous Christmas, and a happy start to the year,
May 2026 bring you love, laughter, and cheer.
From my family to yours, thank you for being part of our crew,
We're looking forward to serving you, in all we do.

All the best

Matty molyneux electrical

🎄 🎅 🎇

If you have a sensor floodlight which no longer works and would like it replaced or would like one fitted in time for th...
24/09/2025

If you have a sensor floodlight which no longer works and would like it replaced or would like one fitted in time for the dark nights. Drop us a message and can arrange a free quote Matty molyneux electrical

💡 ⚡️

When you see connections like this. I automatically know either your husband has attempted to swap them himself , or a b...
24/09/2025

When you see connections like this. I automatically know either your husband has attempted to swap them himself , or a bathroom fitter that thinks he’s a spark himself and replaced them . Always use somebody with competence and know what they’re doing 😃💡 ⚡️

Fusebox update for regular customer in withington this week getting there rental Upto current regulations ⚡️ 💡
24/09/2025

Fusebox update for regular customer in withington this week getting there rental Upto current regulations ⚡️ 💡

Fault find on a job in Ashton this morning due to intermittent tripping at the fusebox. With no rcd protection I knew be...
10/07/2025

Fault find on a job in Ashton this morning due to intermittent tripping at the fusebox. With no rcd protection I knew before I got to the house they was an issue with the live or neutral conductors . On arrival I tested continuity between the live which tested all good, then bingo very high reading on neutral .. socket behind tele was causing the issue, poorly fitted in the past which caused a loose connection /potential fire hazard rectified.
Customer recommended to have a fusebox update.

New light fittings fitted over in levenshulme recently. If you’ve got a tired light fitting or basic pendants throughout...
30/06/2025

New light fittings fitted over in levenshulme recently. If you’ve got a tired light fitting or basic pendants throughout that’s due a change. Drop me a message . Happy to give any advice needed too 💡

All other domestic works undertaken

Matty molyneux electrical

19/12/2024

Thank you to all my customers, both loyal and true,
For trusting Matty Molyneux electrical to see your projects through.
Your recommendations have helped myself and my company grow,
Bringing light and power wherever I go.

As the year comes to a close, we reflect with delight,
On the connections I’ve made, shining ever so bright.
Wishing you a Christmas filled with joy and cheer,
And a New Year ahead that’s bright and clear.

May your homes be warm, your hearts be light,
Thank you for your support, it feels just right.
Here’s to more projects and memories to share,
Happy holidays to all, with love and care!

Matty mol 🙏🏼💙💡💯🎄

8 led spotlights swapped over in Didsbury today. 3 Old low voltage transformers supplying all of the fittings . This mea...
09/12/2024

8 led spotlights swapped over in Didsbury today. 3 Old low voltage transformers supplying all of the fittings . This meant I had to rewire some of the points due to no earth . Drop us a message if your spotlights are due an upgrade or need any advice 💡 💡

Matty molyneux electrical

Call out today to a job over in bramhall due to fan tripping the upstairs lighting circuit once switched on. Caused by h...
21/11/2024

Call out today to a job over in bramhall due to fan tripping the upstairs lighting circuit once switched on. Caused by heat off old halogen bulbs in the spotlights in the bathroom .fittings swapped for fire rated and led bulbs.
Rectified and back up and running 💡 ⚡️